Cabling BOM Estimator

Estimate cable and endpoint materials from planned drops and average run length. Results recalculate in this browser as you edit the inputs.

Inputs

Adjust the estimate

Results update as you change a value. Calculations run in this browser.

drops
ft
ft/drop

Selectable box lengths: 500, 1,000, 2,000, or 3,000 ft.

Live results

Current estimate

Cable per drop

160 ft/drop

Total cable

160 ft

Cable boxes

1 box

Keystone jacks

2 jacks

Faceplates

1 faceplate

24-port patch panels

1 panel

Patch cords

2 cords

Formula and calculation trace

Cable per drop = average run + slack; total cable = drops × cable per drop; boxes = ceil(total cable ÷ box size); jacks = drops × 2; faceplates = drops; 24-port panels = ceil(drops ÷ 24); patch cords = drops × 2.

  1. Per-drop cable: 150 ft average run + 10 ft slack = 160 ft/drop
  2. Total cable: 1 drops × 160 ft/drop = 160 ft
  3. Boxes: ceil(160 ft ÷ 1,000 ft/box) = 1 box
  4. Jacks: 1 drops × 2 ends = 2 jacks
  5. Faceplates: 1 drops × 1 single-port outlet/drop = 1 faceplate
  6. Panels: ceil(1 drops ÷ 24 ports/panel) = 1 panel
  7. Cords: 1 drops × 2 patch cords/drop = 2 cords

Published source: TIA horizontal cabling limit: 90 m (≈295 ft), used as a planning flag.

Assumptions and limits

  • One drop is one horizontal cable run from a telecommunications room to a work-area outlet.
  • Budget two keystone jacks per drop: one work-area end and one telecommunications-room end.
  • Assume one single-port outlet and one faceplate per drop.
  • Each patch panel has 24 ports; panel count is rounded up to a whole panel.
  • Cable-box count is rounded up to a whole selected box length; per-drop slack is included in the total cable.
  • The TIA 90 m (≈295 ft) flag compares only the average horizontal run. It does not change any calculated quantity.

Estimates for planning only, not a substitute for a licensed engineer's design or manufacturer data.