Start with a fiber and application preset, then replace the planning values with manufacturer data when you have it.
Planning estimate
Link loss result
Compare the calculated insertion loss with the selected application's channel limit.
- Fiber loss
- 0.45 dB
- Connector loss
- 1.50 dB
- Splice loss
- 0.00 dB
- Total link loss
- 1.95 dB
- Margin
- +0.95 dB
- Channel limit
- 2.90 dB
Within the loss budget
Calculation details
Formula and calculation trace
- Fiber loss = (150.00 m ÷ 1,000) × 3.00 dB/km = 0.45 dB
- Connector loss = 2 pairs × 0.75 dB = 1.50 dB
- Splice loss = 0 splices × 0.30 dB = 0.00 dB
- Total link loss = 0.45 dB + 1.50 dB + 0.00 dB = 1.95 dB
- Margin = 2.90 dB limit − 1.95 dB = +0.95 dB
Assumptions
- Component values are TIA-568.3-E maximums unless you enter your manufacturer's values.
- MPO trunks with cassettes count each mated pair, including inside cassettes.
- Doesn't model reflectance, bandwidth, dispersion or transceiver power directly.
Planning estimate only. Certify installed links with an OLTS (tier 1) test against the application limit.
Sources
- ANSI/TIA-568.3-E, Optical Fiber Cabling and Components Standard
- IEEE 802.3 (10GBASE-SR/LR, 40GBASE-SR4, 100GBASE-SR4 channel insertion loss limits)