Free planning calculator

PoE Budget Calculator

Estimate switch-level PoE demand by IEEE 802.3 device class. Change counts, budget, or headroom to see the live calculation, remaining capacity, and each formula step.

Inputs

Switch and device load

Free · no sign-in

Example starting values use the required 1,100 W test case. Edit them for your switch; inputs stay in this page only.

15.4 W maximum drawn at the switch (PSE), per device.

devices

30 W maximum drawn at the switch (PSE), per device.

devices

60 W maximum drawn at the switch (PSE), per device.

devices

90 W maximum drawn at the switch (PSE), per device.

devices

Enter the total usable PoE output from the switch specification, in watts.

W

Applied to total device draw before the budget verdict.

%

Starts at 802.3at; select the port class to screen.

Current estimate

PoE budget result

One live result · not saved

Within budget after headroom

Total switch draw

848 W

PoE budget used

77.1%

Required with headroom

1,017.6 W

Additional 802.3at devices

8 devices

77.1%

Entered inputs

802.3af
20 devices
802.3at
10 devices
802.3bt Type 3
4 devices
802.3bt Type 4
0 devices
Switch budget
1,100 W
Headroom
20%

Step-by-step calculation trace

  1. 802.3af draw20 devices × 15.4 W = 308 W
  2. 802.3at draw10 devices × 30 W = 300 W
  3. 802.3bt Type 3 draw4 devices × 60 W = 240 W
  4. 802.3bt Type 4 draw0 devices × 90 W = 0 W
  5. Total draw308 W + 300 W + 240 W + 0 W = 848 W
  6. Budget used848 W ÷ 1,100 W × 100 = 77.1%
  7. Budget with headroom848 W × (1 + 20% ÷ 100) = 1,017.6 W
  8. Verdict1,017.6 W ≤ 1,100 W → within budget
  9. Additional devicesmax(0, floor((1,100 W − 848 W) ÷ 30 W)) = 8

estimates for planning only, not a substitute for a licensed engineer's design or manufacturer data.

Calculations run in this browser without an API request. Inputs are not saved and reset when this page reloads.

Read the estimate

Assumptions, limits & sources

  • Each device is modeled at the listed IEEE 802.3 class maximum drawn from the switch (PSE), not at an assumed lower powered-device (PD) input or measured operating load.
  • The verdict compares total class draw plus the entered headroom with the switch's usable PoE budget. The additional-device count uses remaining budget before headroom, exactly as its separate formula shows.
  • This estimate does not model port-level limits, negotiation details, cable loss, startup transients, PSU redundancy, or manufacturer-specific allocation behavior. Check the switch documentation and engineering design for those constraints.

Class ceiling references: IEEE 802.3af-2003, IEEE 802.3at-2009, and IEEE 802.3bt-2018. Confirm current limits and the switch budget with manufacturer data.