Sample questions and explanations
Question 1 · Module 1: The Mission Critical Site
What best describes a mission critical site?
- A.A facility whose failure would seriously disrupt business operations
- B.A facility that is larger than all other company buildings
- C.A facility that operates only during normal office hours
- D.A facility that houses only office PCs and printers
Correct answer: A — A facility whose failure would seriously disrupt business operations
Explanation: A site is mission critical because of the impact of losing it, not its size. If its services stop, core business processes stop or are seriously harmed.
Question 2 · Module 1: The Mission Critical Site
Why has business dependence on the data centre grown over time?
- A.Fewer customers now use online services than before
- B.More core business processes now run as digital services
- C.Paper records have replaced most electronic systems
- D.Companies now store less data than they used to
Correct answer: B — More core business processes now run as digital services
Explanation: Ordering, payments, communication and records are now largely digital. When those systems depend on the data centre, the business depends on it too.
Question 3 · Module 2: Data Centre Standards
What is the key difference between a standard and a guideline?
- A.A guideline is always legally binding, while a standard is not
- B.A standard is written only for one company, a guideline for countries
- C.A standard sets requirements to follow, while a guideline gives recommendations
- D.There is no practical difference between the two documents
Correct answer: C — A standard sets requirements to follow, while a guideline gives recommendations
Explanation: Standards contain requirements that designs or products are expected to meet. Guidelines advise on good practice but allow more discretion in how they are applied.
Question 4 · Module 2: Data Centre Standards
Which description best fits a regulation?
- A.A voluntary recommendation published by a trade association
- B.A suggestion made by a single equipment manufacturer
- C.An internal preference with no external enforcement
- D.A mandatory rule issued by an authority that must be complied with
Correct answer: D — A mandatory rule issued by an authority that must be complied with
Explanation: Regulations have legal force behind them, so compliance is not optional. Standards and guidelines may become mandatory if a regulation or contract references them.
Question 5 · Module 3: Data Centre Location, Building and Construction
When selecting a data centre site, why is flood history one of the first things to check?
- A.Flood water improves cooling efficiency for the site
- B.A flooded site is cheaper to insure than a dry site
- C.Flooding can disable the whole facility and damage equipment beyond repair
- D.Flood risk only matters for buildings with basements
Correct answer: C — Flooding can disable the whole facility and damage equipment beyond repair
Explanation: Water entering electrical rooms, generators or the computer room can shut the site down and destroy equipment. A site with a known flood risk should normally be avoided or heavily mitigated.
Question 6 · Module 3: Data Centre Location, Building and Construction
Which combination of natural risks should a site selection study assess for a proposed location?
- A.Only the average temperature on the hottest day
- B.Only risks that have occurred in the last month
- C.No natural risks if the building is newly built
- D.Seismic activity, storms and other local natural hazards
Correct answer: D — Seismic activity, storms and other local natural hazards
Explanation: Earthquakes, high winds, storms and similar hazards can damage the building or cut off its utilities. The study should review the hazards that realistically apply to that location.
Question 7 · Module 4: Raised Access Flooring and Suspended Ceiling
What is the primary purpose of a raised access floor in a data centre?
- A.To increase the structural strength of the building slab so heavier racks can be installed
- B.To provide thermal insulation between the data hall and the floor below it
- C.To create a flexible plenum space below the floor for air distribution, cabling and services that can be accessed by lifting panels
- D.To permanently hide all services so they never need to be accessed again
Correct answer: C — To create a flexible plenum space below the floor for air distribution, cabling and services that can be accessed by lifting panels
Explanation: A raised floor creates a usable void underneath. Services in that void can be changed or added by lifting panels, and the same void often distributes cold air.
Question 8 · Module 4: Raised Access Flooring and Suspended Ceiling
How does a stringer-based raised floor system differ from other systems?
- A.Pedestals are glued directly to the panels so the floor acts as one solid sheet
- B.Panels are bolted only at their corners with no support along their edges
- C.Panels rest directly on the slab with no pedestals at regular intervals
- D.Pedestals are connected to each other by horizontal stringers that support the edges of the floor panels
Correct answer: D — Pedestals are connected to each other by horizontal stringers that support the edges of the floor panels
Explanation: In a stringer system the pedestals are linked by stringers. Those stringers add lateral stability and support the panel edges.
Question 9 · Module 5: Light
What does the unit lux measure?
- A.Illuminance, meaning the amount of light falling on a surface per unit area
- B.The total light output emitted by a lamp in all directions
- C.The electrical power consumed by a lighting circuit in one hour
- D.The brightness of a light source as seen looking directly at it
Correct answer: A — Illuminance, meaning the amount of light falling on a surface per unit area
Explanation: Lux measures illuminance on a surface, in lumens per square metre. It tells you how much light actually lands where work is done.
Question 10 · Module 5: Light
What does the unit lumen measure?
- A.The amount of light falling on one square foot of surface
- B.The total amount of visible light emitted by a source
- C.The amount of light falling on one square metre of surface
- D.The ratio between daylight and artificial light in a room
Correct answer: B — The total amount of visible light emitted by a source
Explanation: A lumen measures luminous flux, the total light a source produces. Lux and foot-candles then describe how that light is spread over a surface.
Your score
Rank your sample attempt
Choose your response for each question, then check your score. The answer key and explanations remain visible above.
Exam guide
About the EPI CDCP exam
The Certified Data Centre Professional exam is a 40-question, multiple-choice, closed-book exam with a 1-hour time limit and a passing mark of 27/40. It is accredited by EXIN, and the certificate is valid for 3 years. This sampler uses questions from a validated practice bank.
CDCP syllabus modules
Study distribution based on syllabus topic counts.
| Module | Syllabus topic | Study questions |
|---|---|---|
| 1 | The Mission Critical Site | 26 |
| 2 | Data Centre Standards | 16 |
| 3 | Data Centre Location, Building and Construction | 16 |
| 4 | Raised Access Flooring and Suspended Ceiling | 42 |
| 5 | Light | 26 |
| 6 | Power Infrastructure | 105 |
| 7 | Electro Magnetic Fields | 26 |
| 8 | Equipment Racks | 26 |
| 9 | Cooling Infrastructure | 47 |
| 10 | Water Supply | 11 |
| 11 | Designing a Scalable Network Infrastructure | 42 |
| 12 | Fire Protection | 58 |
| 13 | Physical Security and Safety | 11 |
| 14 | Auxiliary Systems | 48 |
Questions
EPI CDCP sample quiz FAQ
- How many questions are on the EPI CDCP exam, and how long is it?
- The EPI CDCP exam has 40 multiple-choice questions and a 1-hour time limit.
- What is the EPI CDCP passing mark?
- The passing mark is 27 out of 40 questions.
- Who accredits the EPI CDCP exam?
- The EPI CDCP exam is accredited by EXIN.
- How long is the EPI CDCP certificate valid?
- The EPI CDCP certificate is valid for 3 years.
- What does the full CDCP practice hub include?
- The full hub includes a 40-question timed practice exam with saved answers and server-side grading, 10-, 25-, or 50-question practice sessions, missed-question review, and a progress view. Hub access requires a Payhip-verified Deluxe or Complete license.
Exam Samplers
Get sampler updates
Join the LoadCairn — Exam Samplers (website) audience.